Length of the endometrial cavity as measured by uterine sounding and ultrasonography in women of different parities
Abstract
Background
In view of current controversies regarding the need for new, shorter intrauterine devices (IUDs) that would reduce expulsion rates in nulligravida, endometrial cavity length was measured in women of different parities using uterine sounding and ultrasonography.
Study Design
A cross-sectional descriptive study was performed including 570 women of 17–52 years of age, 260 of whom were nulligravida and 310 parous.
Results
The difference in mean length between measurements taken by uterine sounding and ultrasonography was 0.28 cm. Mean endometrial cavity length was 3.84±0.03 cm (mean±S.E.M.) in nulligravida and 4.25±0.03 cm in parous women according to uterine sounding (p<.001) and 3.70±0.03 cm and 3.84±0.03 cm, respectively, according to ultrasonography (p=.006).
Conclusions
By either technique, mean length of the endometrial cavity was >3.6 cm, the length of the most common IUDs, the TCu380A and the levonorgestrel-releasing intrauterine system. Therefore, the issue appears controversial for developing new, shorter IUDs, since current models fit most women, including nulligravida, albeit one third of the women of our sample showed endometrial length shorter than 3.2 cm.
Keywords: Endometrial length, Nulligravida women, Parous women, Intrauterine device
To access this article, please choose from the options below
PII: S0010-7824(10)00007-7
doi:10.1016/j.contraception.2010.01.006
© 2010 Elsevier Inc. All rights reserved.