Contraception
Volume 85, Issue 1 , Pages 99-107, January 2012

Couples' acceptability of the SILCS diaphragm for microbicide delivery

  • Ron G. Frezieres

      Affiliations

    • California Family Health Council, Los Angeles, CA 90010, USA
  • ,
  • Terri Walsh

      Affiliations

    • California Family Health Council, Los Angeles, CA 90010, USA
  • ,
  • Maggie Kilbourne-Brook

      Affiliations

    • Program for Appropriate Technology in Health (PATH), Seattle, WA 98121, USA
  • ,
  • Patricia S. Coffey

      Affiliations

    • Program for Appropriate Technology in Health (PATH), Seattle, WA 98121, USA
    • Corresponding Author InformationCorresponding author. Tel.: +1 206 285 3500; fax: +1 206 285 6619.

Received 9 February 2011; received in revised form 6 April 2011; accepted 8 April 2011. published online 12 August 2011.

Abstract 

Background

Disposable plastic applicators used in microbicide gel studies are expensive and have a negative environmental impact. The SILCS diaphragm is a barrier contraceptive that could offer a reusable delivery system.

Study Design

Thirty-six couples in this randomized, cross-over study evaluated single- and double-sided gel delivery from a SILCS diaphragm compared with gel from an applicator. Couples used each gel scenario during two acts of intercourse and completed acceptability questionnaires after each.

Results

All three scenarios received favorable ratings for ease of application, acceptability and perceived effectiveness. Both female and male participants tended to rate the gel applicator significantly more favorably than either SILCS gel delivery scenarios for all attributes except messiness/leakage and effectiveness. Additionally, about 60% of female participants and about half of male participants preferred the gel applicator to either of the gel delivery systems using SILCS. The preference for the SILCS scenario for pregnancy protection was statistically significant for both sexes. Male participants were also significantly more likely to prefer the SILCS single-sided delivery system to the gel applicator for protection from sexually transmitted infection.

Conclusions

In this study population, participants found the gel applicator to be more acceptable than either single- or double-sided gel delivery from a SILCS diaphragm. Further research of the SILCS as a microbicide delivery system should be implemented to assess its acceptability among study populations that reflect diverse potential user groups such as women and men from both low and high HIV prevalence settings including HIV-positive populations and with and without experience using female barrier methods.

Keywords: Contraception, Diaphragm, SILCS, Acceptability, Microbicide delivery

 

PII: S0010-7824(11)00162-4

doi:10.1016/j.contraception.2011.04.003

Contraception
Volume 85, Issue 1 , Pages 99-107, January 2012