      Abstract

      Five intrauterine devices (IUDs) are available in the United States: four levonorgestrel-releasing intrauterine systems (two containing 52 mg, one containing 19.5 mg and one containing 13.5 mg) and one copper-bearing device (Copper T 380A). All IUDs have very low typical-use failure rates and high acceptability ratings, yet they are used by a minority of women, with nulliparous women less likely to do so than parous women. The objective of this clinical review is to give evidence-based recommendations for the use of IUDs in nulliparous women. Intrauterine devices are safe and effective for the majority of women including those who are nulliparous, and should be routinely included in the contraception options offered to them.

      Keywords

      This guideline revises and replaces the first version published in 2009. During the past 7 years, there have been significant contributions to the literature on the use of intrauterine devices (IUDs) in nulliparous women. These data have enabled us to make more confident statements about the effectiveness, acceptability and low complication rate of IUD use in this group. They have also provided concrete information on the role of preinsertion agents, which do not appear to provide any benefit. In addition, although some studies have shown that nulliparous women may be more likely to experience difficult or painful insertions, the vast majority of women, regardless of parity, experience successful and well-tolerated insertions. Recent research, like earlier studies, shows that both providers and women frequently have an inadequate understanding of IUDs. This lack of knowledge is a major barrier to wider use.
      This guideline is not itself a systematic review of the literature, although we include the results of systematic reviews where available. Some of the questions addressed in this guideline are not amenable to systematic reviews because of the limitations of the information available on the IUDs currently being marketed. Rather, this document provides guidance for clinical practice based on a synthesis of expert opinion and available evidence.
      In summary, data published since 2009 have confirmed that IUDs are an excellent contraceptive option for nulliparous women. However, the health care community and the public need to be educated about their safety, effectiveness and acceptability in this group to improve access and an informed choice of contraceptive method.

      1. Background

      IUDs are highly effective, safe and well-tolerated contraceptives with typical-use failure rates similar to that of surgical sterilization [
      • Trussell J.
      Contraceptive failure in the United States.
      ]. These characteristics make the IUD an excellent contraceptive for the majority of women, including those who are nulliparous.
      The overall use of IUDs has increased in recent years. In 2002, 2% of currently contracepting women reported use of an IUD [
      • Daniels K.
      • Daugherty J.
      • Jones J.
      • Mosher W.
      Current contraceptive use and variation by selected characteristics among women aged 15–44: United States, 2011–2013.
      ]. This proportion rose to 10.3% by the period 2011–2013. Use of IUDs has also grown among nulliparous women, although to a lesser extent. In 2002, only 0.5% of women currently using contraception who had never had a birth were using an IUD. This grew to 4.8% in 2011–2013.
      The belief that women must have had at least one vaginal delivery to be eligible for an IUD remains a barrier to provision to women who are nulliparous. A survey obstetrician-gynecologists in the United States found that only two thirds considered nulliparous women appropriate candidates for IUDs [
      • Luchowski A.T.
      • Anderson B.L.
      • Power M.L.
      • Raglan G.B.
      • Espey E.
      • Schulkin J.
      Obstetrician-gynecologists and contraception: practice and opinions about the use of IUDs in nulliparous women, adolescents and other patient populations.
      ]. Another study based on a questionnaire completed by clinicians, including physicians, physician assistants, certified nurse midwives, nurse practitioners and nurses, found that 30% of respondents had misconceptions about the safety of IUD use in nulliparous women [
      • Tyler C.P.
      • Whiteman M.K.
      • Zapata L.B.
      • Curtis K.M.
      • Hillis S.D.
      • Marchbanks P.A.
      Health care provider attitudes and practices related to intrauterine devices for nulliparous women.
      ]. Particular concerns cited are the risk of pelvic inflammatory disease (PID) and infertility, and the safety and difficulty of insertion [
      • Stanwood N.L.
      • Garrett J.M.
      • Konrad T.R.
      Obstetrician-gynecologists and the intrauterine device: a survey of attitudes and practice.
      ,
      • Harper C.C.
      • Blum M.
      • de Bocanegra H.T.
      • Darney P.D.
      • Speidel J.J.
      • Policar M.
      • et al.
      Challenges in translating evidence to practice: the provision of intrauterine contraception.
      ,
      • Madden T.
      • Allsworth J.E.
      • Hladky K.J.
      • Secura G.M.
      • Peipert J.F.
      Intrauterine contraception in Saint Louis: a survey of obstetrician and gynecologists' knowledge and attitudes.
      ].
      Outdated and some current prescribing information may also contribute to misperceptions about the relationship between parity and eligibility for an IUD. For example, when the Copper T 380A was first marketed in the United States, it included a history of childbirth as part of a recommended patient profile. Although the label was changed in 2005 to remove this recommendation, many current providers may not be aware of the change []. The prescribing information for one of the 52-mg levonorgestrel intrauterine systems (brand name Mirena) currently recommends the device for women who have had one child []. Neither the label for the more recently marketed 52-mg system (brand name Liletta) [] nor that of the devices designed for smaller uteri, the 19.5-mg levonorgestrel-releasing intrauterine system (LNG-IUS; brand name Kyleena) [] or the 13.5-mg LNG-IUS (brand name Skyla) [], mentions parity with regard to eligibility. While not explicitly addressed, the prescribing information of these products includes data on their use in parous and nulliparous participants, suggesting no limit based on a history of previous birth.
      In its Medical Eligibility Criteria for Contraceptive Use (U.S.-MEC), the Centers for Disease Control designate intrauterine contraception for nulliparous women as Category 2 (advantages generally outweigh risks), while for parous women, it is Category 1 (no restriction) [
      • Curtis K.M.
      • Tepper N.K.
      • Jatlaoui T.C.
      • Berry-Bibee E.
      • Horton L.G.
      • Zapata L.B.
      • et al.
      U.S. medical eligibility criteria for contraceptive use, 2016.
      ]. The U.S.-MEC states: “The data conflict about whether IUD use is associated with infertility among nulliparous women, although well-conducted studies suggest no increased risk.” Although the Selected Practice Recommendations [
      • Curtis K.M.
      • Jatlaoui T.C.
      • Tepper N.K.
      • Zapata L.B.
      • Horton L.G.
      • Jamieson D.J.
      • et al.
      U.S. selected practice recommendations for contraceptive use, 2016.
      ] make clear that parity need not influence eligibility for an IUD, such statements may discourage use of IUDs in nulliparous women.
      Many young women appear to have limited or no awareness of IUDs [
      • Fleming K.L.
      • Sokoloff A.
      • Raine T.R.
      Attitudes and beliefs about the intrauterine device among teenagers and young women.
      ,
      • Rose S.B.
      • Cooper A.J.
      • Baker N.K.
      • Lawton B.
      Attitudes toward long-acting reversible contraception among young women seeking abortion.
      ,
      • Spies E.L.
      • Askelson N.M.
      • Gelman E.
      • Losch M.
      Young women's knowledge, attitudes, and behaviors related to long-acting reversible contraceptives.
      ,
      • Stanwood N.L.
      • Bradley K.A.
      Young pregnant women's knowledge of modern intrauterine devices.
      ,
      • Whitaker A.K.
      • Johnson L.M.
      • Harwood B.
      • Chiappetta L.
      • Creinin M.D.
      • Gold M.A.
      Adolescent and young adult women's knowledge of and attitudes toward the intrauterine device.
      ]. However, nulliparous women who do use IUDs have a generally positive view of them [
      • Wiebe E.R.
      • Trouton K.J.
      • Dicus J.
      Motivation and experience of nulliparous women using intrauterine contraceptive devices.
      ].
      This guideline reviews the evidence on IUD use in nulliparous women. While other devices are available worldwide and will be discussed briefly, this review focuses on the five available in the United States:
      • The Copper T 380A, a copper-bearing T-shaped IUD measuring 36 mm by 32 mm with an approved duration of use of 10 years (Paragard)
      • Four T-shaped LNG-IUSs:
        • o
          Two LNG-IUSs that contain 52 mg of levonorgestrel and measure 32 mm by 32 mm. One (Mirena) is approved for 5 years of use, while the other (Liletta) is currently approved for 3 years. With continued follow-up of women in the Phase III trials, the duration of use of Liletta will likely be extended to 7 years.
        • o
          A smaller LNG-IUS containing 19.5 mg of levonorgestrel, which measures 30 mm by 28 mm and is approved for 5 years of use (Kyleena). Like the device itself, the diameter of the insertion tube is smaller than those of other IUDs.
        • o
          A smaller LNG-IUS containing 13.5 mg of levonorgestrel, which measures 30 mm by 28 mm and is approved for 3 years of use (Skyla). Like the device itself, the diameter of the insertion tube is smaller than those of other IUDs.

      2. Clinical questions

      2.1 What is the failure rate of IUDs in nulliparous women?

      Intrauterine contraception has a low failure rate in both multiparous and nulliparous women. In the first year, the failure rate during typical use is 0.2% for the 52-mg LNG-IUS and 0.8% for the Copper T 380A [
      • Trussell J.
      Contraceptive failure in the United States.
      ]. Perfect-use failure rates are 0.2% and 0.6%, respectively. Although typical-use failure rates for the 13.5-mg LNG-IUS or the 19.5-mg LNG-IUS are not yet available, a Phase III randomized trial of 1432 women (including 556 nulliparous women) who used the smaller devices for up to 3 years found cumulative failure rates of 0.9% and 1%, respectively. Seven hundred and seven women randomized to the 19.5-mg system elected to enter into a two-year extension study [
      • Gemzell-Danielsson K.
      • Apter D.
      • Dermout S.
      • Faustmann T.
      • Rosen K.
      • Schmelter T.
      • et al.
      Evaluation of a new, low-dose levonorgestrel intrauterine contraceptive system over 5 years of use.
      ], enabling a 5-year cumulative failure rate to be calculated which was 1.5% [
      • Gemzell-Danielsson K.
      • Apter D.
      • Dermout S.
      • Faustmann T.
      • Rosen K.
      • Schmelter T.
      • et al.
      Evaluation of a new, low-dose levonorgestrel intrauterine contraceptive system over 5 years of use.
      ].
      Comparisons of IUD failure rates by parity confirm a low rate in nulliparous women. Sivin and Stern reported on 11 trials of the Copper T380A performed by the Population Council in the early 1970s in which 64% of participants were nulliparous, and found no marked difference by parity [
      • Sivin I.
      • Stern J.
      Long-acting, more effective copper T IUDs: a summary of U.S. experience, 1970–75.
      ]. A more recent multicenter retrospective chart review of 2138 women aged 13–35 who used either the 52-mg LNG-IUS or the Copper T 380A also found no significant differences in rates of pregnancy between women of differing parity [
      • Aoun J.
      • Dines V.A.
      • Stovall D.W.
      • Mete M.
      • Nelson C.B.
      • Gomez-Lobo V.
      Effects of age, parity, and device type on complications and discontinuation of intrauterine devices.
      ]. Life-table analysis of 1600 16–35-year-old women (including 989 nulliparous women) in a Phase III study of the newer 52-mg LNG-IUS (Liletta) yielded a pregnancy rate of 0.14 [95% confidence interval (CI) 0.04–0.57] through 1 year and 0.55 (95% CI 0.24–1.23) through 3 years [
      • Eisenberg D.L.
      • Schreiber C.A.
      • Turok D.K.
      • Teal S.B.
      • Westhoff C.L.
      • Creinin M.D.
      • et al.
      Three-year efficacy and safety of a new 52-mg levonorgestrel-releasing intrauterine system.
      ]. Two pregnancies were reported in 989 nulliparous women and 4 of 611 parous women, suggesting no difference. A subanalysis of the Phase III trial of the 13.5-mg and 19.5-mg LNG systems and the extension study of the 19.5-mg LNG-IUS also demonstrated no difference in efficacy by parity [
      • Gemzell-Danielsson K.
      • Apter D.
      • Dermout S.
      • Faustmann T.
      • Rosen K.
      • Schmelter T.
      • et al.
      Evaluation of a new, low-dose levonorgestrel intrauterine contraceptive system over 5 years of use.
      ,
      • Gemzell-Danielsson K.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
      ].
      A number of smaller studies of IUD use in nulliparous women demonstrate their high, expected effectiveness in this group. In a randomized trial by Suhonen et al., comparing the 52-mg LNG-IUS with oral contraceptives (OCs) [
      • Suhonen S.
      • Haukkamaa M.
      • Jakobsson T.
      • Rauramo I.
      Clinical performance of a levonorgestrel-releasing intrauterine system and oral contraceptives in young nulliparous women: a comparative study.
      ], no pregnancies occurred in 94 nulliparous women assigned to the LNG-IUS during 1 year of use. In another prospective pilot study [
      • Brockmeyer A.
      • Kishen M.
      • Webb A.
      Experience of IUD/IUS insertions and clinical performance in nulliparous women — a pilot study.
      ], there were no pregnancies among a cohort of nulliparous women using either the 52-mg LNG-IUS (n=9) or copper-bearing devices (n=104) at 1 year. Lastly, a study from Belgium of a T-shaped levonorgestrel-releasing device similar to a 52-mg LNG-IUS included 112 nulliparous women and reported no pregnancies over the 5-year study period [
      • Wildemeersch D.
      • Janssens D.
      • Vrijens M.
      • Weyers S.
      Ease of insertion, contraceptive efficacy and safety of new T-shaped levonorgestrel-releasing intrauterine systems.
      ].

      2.2 Is intrauterine contraception acceptable to nulliparous women?

      High satisfaction and continuation rates are reported in studies of both the Copper T380A and LNG-IUS. Among women enrolled in the Contraceptive CHOICE project, 85% of LNG-IUS users (n=1551) and 80% of Copper T380A users (n=385) were very or somewhat satisfied at 12 months, rates that the authors reported were unaffected by parity [
      • Peipert J.F.
      • Zhao Q.
      • Allsworth J.E.
      • Petrosky E.
      • Madden T.
      • Eisenberg D.
      • et al.
      Continuation and satisfaction of reversible contraception.
      ]. Continuation rates, also unaffected by parity, were 88% and 84%, respectively. A small prospective study of 109 nulliparous students at a university health clinic found that 83% of users were “happy” or “very happy” with the IUD, and 87% reported that they were “likely” or “very likely” to recommend it to a friend [
      • Hall A.M.
      • Kutler B.A.
      Intrauterine contraception in nulliparous women: a prospective survey.
      ]. There were no statistically significant differences in satisfaction between users of the LNG-IUS and those of the Copper T 380A in that study.
      In Europe and the Near East, a survey of 8680 users of the LNG-IUS (8% of whom were nulliparous) found that 93% of nulliparous women reported satisfaction with device (62% very satisfied and 31% rather satisfied) compared with 95% of women with children (66% very satisfied and 29% rather satisfied) [
      • Römer T.
      • Linsberger D.
      User satisfaction with a levonorgestrel-releasing intrauterine system (LNG-IUS): data from an international survey.
      ]. Overall, 86% and 91% of nulliparous women and women with children, respectively, would recommend the LNG-IUS to a friend, while 87% and 91% stated their intention to have LNG-IUS fitted again. The randomized trial by Suhonen et al. found that 90% of women in the LNG-IUS group and 88% in the OC group assessed their methods as being moderately to very good (p=.36) [
      • Eisenberg D.L.
      • Schreiber C.A.
      • Turok D.K.
      • Teal S.B.
      • Westhoff C.L.
      • Creinin M.D.
      • et al.
      Three-year efficacy and safety of a new 52-mg levonorgestrel-releasing intrauterine system.
      ]. However, 86% of LNG-IUS users who completed the 1-year study were willing to continue with the same method compared to only 68% of OC users (p=.003).
      In the subanalysis of the Phase III trial of the smaller 13.5-mg LNG-IUS and a 19.5-mg LNG-IUS, 2116 of 2884 women in the full analysis set completed a user satisfaction questionnaire either at the end of 3 years (those who completed the study) or at their last study visit (those who discontinued prematurely): 802 and 1314 were nulliparous and parous, respectively [
      • Gemzell-Danielsson K.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
      ]. Across all parity subgroups, >90% of women were either “very satisfied” or “somewhat satisfied” with these devices.

      2.3 Is the rate of IUD expulsion higher among nulliparous women than among parous women?

      In 2007, Hubacher published a systematic review comparing the performance of a range of copper IUDs in nulliparous and parous women [
      • Hubacher D.
      Copper intrauterine device use by nulliparous women: review of side effects.
      ]. Expulsions were rated as higher for nulliparous women in 13 of 20 studies examined; however, for the Copper T380A, performance differed only slightly between nulliparous and parous women [
      • Sivin I.
      • Stern J.
      Long-acting, more effective copper T IUDs: a summary of U.S. experience, 1970–75.
      ].
      More recent studies have reported equivalent or lower rates of expulsion in nulliparous compared to multiparous women. In the multicenter retrospective study by Aoun et al., of 2138 IUD users aged 13–35 years, the overall rate of IUD expulsion was 6%, which did not significantly differ by parity (p=.79) [
      • Aoun J.
      • Dines V.A.
      • Stovall D.W.
      • Mete M.
      • Nelson C.B.
      • Gomez-Lobo V.
      Effects of age, parity, and device type on complications and discontinuation of intrauterine devices.
      ]. The Contraceptive CHOICE project, which included 4219 women choosing the LNG-IUS and 1184 choosing the Copper T 380A, found a cumulative expulsion rate of 10.2 per 100 IUD users over a 36-month study period, with no differences by IUD type [
      • Madden T.
      • McNicholas C.
      • Zhao Q.
      • Secura G.M.
      • Eisenberg D.L.
      • Peipert J.F.
      Association of age and parity with intrauterine device expulsion.
      ]. The cumulative rate of expulsion was lower in nulliparous women compared with parous women (8.4 vs. 11.4; p<.001). After adjusting for confounders and stratifying by IUD type, expulsion was lower for nulliparous LNG-IUS users (adjusted hazard ratio 0.59, 95% CI 0.44–0.78) and was higher for copper IUD users, but this did not reach statistical significance, (14.3 compared with 8.2, p=.10). Similarly, in the 3-year efficacy trial of the newer 52-mg LNG-IUS (Liletta), expulsion occurred less frequently in nulliparous women than parous women (2% vs. 5.6%, p<.0001) [
      • Eisenberg D.L.
      • Schreiber C.A.
      • Turok D.K.
      • Teal S.B.
      • Westhoff C.L.
      • Creinin M.D.
      • et al.
      Three-year efficacy and safety of a new 52-mg levonorgestrel-releasing intrauterine system.
      ]. Lower rates of expulsions among nulliparous women were also reported in subanalysis of the Phase III trial of the smaller 13.5-mg and 19.5-mg LNG systems [
      • Gemzell-Danielsson K.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
      ].

      2.4 Are side effects higher in nulliparous women than in parous women?

      Expected side effects of the LNG-IUS devices are lighter menstrual bleeding and a tendency toward amenorrhea. In the first 3 months, there may be irregular bleeding. Common side effects reported for the Copper T 380A are increased menstrual bleeding and pain.
      Hubacher reported that removals of copper-bearing IUDs for pain and bleeding were higher in nulliparous than in parous women and that IUD size and shape play a role in performance [
      • Hubacher D.
      Copper intrauterine device use by nulliparous women: review of side effects.
      ]. The one study included in this analysis that investigated the Copper T 380A found a removal rate attributed to bleeding and pain at 2 years of use to be significantly higher for the Copper T 380A than the Copper T 200 in the double-blind studies (23.7 vs. 18.9 per 100, p<.01) [
      • Nelson A.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial.
      ]. The differential was strongly marked in the nulliparous acceptors at 2 years (24.6 vs. 17.6, p<.01).
      Aoun's multisite retrospective study of the copper IUD and LNG-IUS [
      • Aoun J.
      • Dines V.A.
      • Stovall D.W.
      • Mete M.
      • Nelson C.B.
      • Gomez-Lobo V.
      Effects of age, parity, and device type on complications and discontinuation of intrauterine devices.
      ] also found that nulliparous women were more likely to report pain with IUD use than were parous women (p=.02), although the incidence of discontinuation was not greater in the nulliparous group (p=.13). Comparison between the two devices was not made, however. Suhonen documented that, among nulliparous women randomized to the LNG-IUS, pain was the most common reason for IUS discontinuation at 12 months, reported in 6 of 94 women [
      • Suhonen S.
      • Haukkamaa M.
      • Jakobsson T.
      • Rauramo I.
      Clinical performance of a levonorgestrel-releasing intrauterine system and oral contraceptives in young nulliparous women: a comparative study.
      ]. Most of the discontinuations for pain (4 out of 6) occurred during the first 3 months after insertion. A change in menstrual bleeding pattern (including amenorrhea) was the indication for discontinuation of both the 13.5-mg and 19.5-mg LNG-IUS in approximately 5% of women in the Phase III efficacy trial but did not differ by parity [
      • Gemzell-Danielsson K.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
      ].
      While pain and problematic bleeding appear to be more common in nulliparous users of copper-bearing devices and short-term changes in menstrual pattern occur with the LNG-IUS regardless of parity, in most cases, they are not sufficiently problematic to result in device removal.
      Symptomatic ovarian cysts are a known adverse event associated with LNG-IUS use. Eisenberg et al. reported on cyst formation in parous and nulliparous women in the Phase III trial of the 52-mg LNG-IUS (Liletta) [
      • Eisenberg D.L.
      • Schreiber C.A.
      • Turok D.K.
      • Teal S.B.
      • Westhoff C.L.
      • Creinin M.D.
      • et al.
      Three-year efficacy and safety of a new 52-mg levonorgestrel-releasing intrauterine system.
      ]. Fifty-nine (3.4%) women had a symptomatic ovarian cyst, including 3.2% of nulliparous women and 3.7% of parous women (p=.15).

      2.5 Is the risk of perforation at IUD insertion higher in nulliparous women than in parous women?

      The overall risk of uterine perforation with IUD insertion is low. In a European multinational, prospective, noninterventional cohort study, the rate reported with the LNG-IUS was 1.4 per 1000 insertions (95% CI 1.1–1.8) and 1.1 per 1000 insertions (95% CI 0.7–1.7) for copper IUDs [
      • Heinemann K.
      • Reed S.
      • Moehner S.
      • Minh T.D.
      Risk of uterine perforation with levonorgestrel-releasing and copper intrauterine devices in the European active surveillance study on intrauterine devices.
      ]. This risk could theoretically be higher in nulliparous women because of their smaller uterine cavity and greater cervical resistance to dilation, but evidence for a difference is limited.
      One prospective follow-up study reported that increasing parity reduced the risk of perforation with insertion of the Copper T 380A, but included only two nulliparous women in a total of 8343 women [
      • Caliskan E.
      • Oztürk N.
      • Dilbaz B.O.
      • Dilbaz S.
      Analysis of risk factors associated with uterine perforation by intrauterine devices.
      ]. Neither Suhonen et al. nor Brockmeyer et al. reported perforations during their studies of IUDs in nulliparous women [
      • Suhonen S.
      • Haukkamaa M.
      • Jakobsson T.
      • Rauramo I.
      Clinical performance of a levonorgestrel-releasing intrauterine system and oral contraceptives in young nulliparous women: a comparative study.
      ,
      • Brockmeyer A.
      • Kishen M.
      • Webb A.
      Experience of IUD/IUS insertions and clinical performance in nulliparous women — a pilot study.
      ]. Veldhuis et al. reported no perforations among 461 women (129 nulliparous and 332 parous) who had one or more Copper IUD or LNG-IUS insertions between 1981 and 2000 in general practice in the Netherlands [
      • Veldhuis H.
      • Vos A.
      • Lagro-Janssen A.
      Complications of the intrauterine device in nulliparous and parous women.
      ].

      2.6 Is the risk of PID higher in nulliparous than in parous users of intrauterine contraception?

      An older epidemiologic study [
      • Farley T.M.
      • Rosenberg M.J.
      • Rowe P.J.
      • Chen J.H.
      • Meirik O.
      Intrauterine devices and pelvic inflammatory disease: an international perspective.
      ] found small transitory increase in the incidence of pelvic infection in the first 20 days after IUD insertion, thought to be related to either cervical infection at the time of insertion or transmission of vaginal bacteria into the uterus. However, a systematic review of more recent direct and indirect evidence found that IUD placement in women with asymptomatic gonorrhea or Chlamydia infection or at high risk of sexually transmitted infections did not have an increase in the risk of PID compared to initiating other contraceptive methods [
      • Jatlaoui T.C.
      • Simmons K.B.
      • Curtis K.M.
      The safety of intrauterine contraception initiation among women with current asymptomatic cervical infections or at increased risk of sexually transmitted infections.
      ]. Prospective observational data from the Phase III trial of the 52-mg LNG-IUS (Liletta) provide further evidence that there is no increased risk of PID in the weeks following insertion among a low-risk population [
      • Turok D.K.
      • Eisenberg D.L.
      • Teal S.B.
      • Keder L.M.
      • Creinin M.D.
      A prospective assessment of pelvic infection risk following same-day sexually transmitted infection testing and levonorgestrel intrauterine system placement.
      ]. It is important to note that even in the presence of risk factors and undiagnosed infection, the absolute risk of PID is low. Screening for cervical infection can be performed at the time of insertion, followed by treatment as indicated.
      Although studies reporting comparisons are few, parity does not seem to affect the risk of PID after IUD insertion. Veldhuis et al. reported no difference in the rate of PID among nulliparous and parous women who had either a copper IUD or LNG-IUS placed [
      • Veldhuis H.
      • Vos A.
      • Lagro-Janssen A.
      Complications of the intrauterine device in nulliparous and parous women.
      ]. Over up to 3 years of the 13.5-mg LNG-IUS or 19.5-mg LNG-IUS use, nulliparous women were at no higher risk PID than parous women (crude PID incidence: 0.1% vs. 0.6%, respectively) [
      • Gemzell-Danielsson K.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
      ]. In Suhonen's randomized controlled trial of 193 nulliparous women aged 18–25 years randomized to LNG-IUS or OCs, no PID cases were reported among the total study population over 12 months [
      • Suhonen S.
      • Haukkamaa M.
      • Jakobsson T.
      • Rauramo I.
      Clinical performance of a levonorgestrel-releasing intrauterine system and oral contraceptives in young nulliparous women: a comparative study.
      ].

      2.7 Are nulliparous users of IUDs at higher risk of infertility than parous users?

      Intrauterine devices have long been believed to cause PID and subsequent tubal infertility. However, in a landmark case–control study, Hubacher et al. demonstrated that infection with Chlamydia trachomatis, not previous use of a copper IUD, is associated with an increased risk of tubal occlusion among nulligravid women [
      • Hubacher D.
      • Lara-Ricalde R.
      • Taylor D.J.
      • Guerra-Infante F.
      • Guzman-Rodriguez R.
      Use of copper intrauterine devices and the risk of tubal infertility among nulligravid women.
      ].
      One older study of return to fertility among nulliparous women discontinuing OCs, the copper IUD or a barrier method found the return of fertility to be slowest in the first 12 months among OC users, the fastest in those discontinuing barrier methods with those discontinuing copper IUDs midway between [
      • Doll H.
      • Vessey M.
      • Painter R.
      Return of fertility in nulliparous women after discontinuation of the intrauterine device: comparison with women discontinuing other methods of contraception.
      ]. By 18 months, the differences had disappeared. More recent data regarding the LNG-IUS and a copper-based IUD still widely used in Europe found no delay in return of fertility after discontinuation [
      • Andersson K.
      • Batar I.
      • Rybo G.
      Return to fertility after removal of a levonorgestrel-releasing intrauterine device and Nova-T.
      ]. The only study directly comparing the return to fertility in nulliparous and parous users after cessation of use of the GyneFix device (a frameless copper-based IUD not available in the United States) found no difference between the two groups [
      • Delbarge W.
      • Bátár I.
      • Bafort M.
      • Bonnivert J.
      • Colmant C.
      • Dhont M.
      • et al.
      Return to fertility in nulliparous and parous women after removal of the GyneFix intrauterine contraceptive system.
      ].

      2.8 Is IUD insertion more painful or difficult in nulliparous women?

      Most IUD insertions in nulliparous women occur without complication [
      • Harvey C.
      • Bateson D.
      • Wattimena J.
      • Black K.I.
      Ease of intrauterine contraceptive device insertion in family planning settings.
      ] but may be more painful, more difficult and less likely to be successful compared to IUD insertion in parous women.

      2.8.1 Pain

      Several studies have found that women with a prior vaginal delivery report less pain at IUD insertion than women with no prior vaginal delivery. The magnitude of the recorded difference in pain varies across studies. One study found the mean pain score on a 0–100-mm visual analog scale (VAS) to be 51.2 (SD 29.2) for nulliparous women and 34.7 (SD 31.6) for parous women (p=.009) [
      • Allen R.H.
      • Carey M.S.
      • Raker C.
      • Goyal V.
      • Matteson K.
      A prospective cohort study of pain with intrauterine device insertion among women with and without vaginal deliveries.
      ]. In a retrospective review, a small but statistically significant increase in insertion discomfort was found for nulliparous women, but the authors doubted the clinical importance of the finding [
      • Brown W.M.
      • Trouton K.
      Intrauterine device insertions: which variables matter?.
      ].
      In a study showing no benefit of preinsertion ibuprofen, Hubacher [
      • Hubacher D.
      Pain from copper intrauterine device insertion: randomized trial of prophylactic ibuprofen.
      ] found a low but statistically significant difference between pain ratings in nulliparous and multiparous women (2.7 and 1.9 on a 10-cm VAS, respectively). Another study showing no benefit of ibuprofen prior to IUD insertion found higher pain scores overall than those reported by Hubacher's group and also reported a significant difference between nulliparous and parous women (54.6 and 35.0 on a 100-mm VAS, respectively) [
      • Bednarek P.H.
      • Creinin M.D.
      • Reeves M.F.
      • Cwiak C.
      • Espey E.
      • Jensen J.T.
      Prophylactic ibuprofen does not improve pain with IUD insertion: a randomized trial. Post-aspiration IUD randomization (PAIR) study trial group.
      ]. Other studies have found similarly high VAS scores, between 5 and 6, for nulliparous women undergoing IUD insertion, although these studies do not include parous women for comparison, limiting the potential to draw a definitive conclusion from these data [
      • Espey E.
      • Singh R.H.
      • Leeman L.
      • Ogburn T.
      • Fowler K.
      • Greene H.
      Misoprostol for intrauterine device insertion in nulliparous women: a randomized controlled trial.
      ,
      • Swenson C.
      • Turok D.K.
      • Ward K.
      • Jacobson J.C.
      • Dermish A.
      Self-administered misoprostol or placebo before intrauterine device insertion in nulliparous women: a randomized controlled trial.
      ].
      In an effort to reduce discomfort, some clinicians routinely provide an oral nonsteroidal anti-inflammatory drug prior to insertion. While these medications have a low cost and a low incidence of side effects, a Cochrane review of the available evidence found that they are not effective at reducing pain during or after insertion [
      • Lopez L.M.
      • Bernholc A.
      • Zeng Y.
      • Allen R.H.
      • Bartz D.
      • O'Brien P.A.
      • et al.
      Interventions for pain with intrauterine device insertion.
      ]. Ketorolac given 30 min prior to IUD insertion was studied and found to decrease pain with uterine sounding (8.4 cm vs. 6.0 cm on a 10-cm VAS, p=.04), at IUD placement (8.1 cm vs. 5.4 cm, p=.02) and at 15 min postprocedure (4.8 cm vs. 1.8 cm, p=.02) [
      • Ngo L.L.
      • Ward K.K.
      • Mody S.K.
      Ketorolac for pain control with intrauterine device placement: a randomized controlled trial.
      ]. Unfortunately, at 15 min postinsertion, 20% of the subjects also rated the pain of injection as equivalent to the pain of IUD insertion. Other measures that have been studied and are not effective are 1% or 2% lidocaine gel via the cervical [
      • Allen R.H.
      • Raker C.
      • Goyal V.
      Higher dose cervical 2% lidocaine gel for IUD insertion: a randomized controlled trial.
      ] and vaginal [
      • Rapkin R.B.
      • Achilles S.L.
      • Boraas C.
      • Cremer M.
      • Schwarz E.B.
      • Chen B.A.
      Self-administered lidocaine gel for intrauterine device insertion in nulliparous women: a randomized controlled trial.
      ] routes, and nitroglycerin gel via the cervical [
      • Bednarek P.H.
      • Micks E.A.
      • Edelman A.B.
      • Li H.
      • Jensen J.T.
      The effect of nitroprusside on IUD insertion experience in nulliparous women: a pilot study.
      ] and vaginal [
      • Micks E.A.
      • Jensen J.T.
      • Bednarek P.H.
      The effect of nitroglycerin on the IUD insertion experience in nulliparous women: a pilot study.
      ] routes. One randomized controlled trial of 218 nulliparous women receiving administration 4% viscous lidocaine delivered to the portio, cervix and uterus did find significantly lower pain scores within 10 min of insertion (28.3 mm vs. 44.2 mm on a 100-mm VAS, p<.0001) [
      • Tornblom-Paulander S.
      • Tingåker B.K.
      • Werner A.
      • Liliecreutz C.
      • Conner P.
      • Wessel H.
      • et al.
      Novel topical formulation of lidocaine provides significant pain relief for intrauterine device insertion: pharmacokinetic evaluation and randomized placebo-controlled trial.
      ]. This study did not adequately measure the pain of study drug application. Misoprostol, a prostaglandin analogue administered for cervical priming before a range of gynecological procedures, is used by many clinicians before IUD insertion in nulliparous women [
      • Ward K.
      • Jacobson J.C.
      • Turok D.K.
      • Murphy P.A.
      A survey of provider experience with misoprostol to facilitate intrauterine device insertion in nulliparous women.
      ]. However studies have consistently shown that misoprostol is not effective at reducing pain or difficulty of insertion [
      • Espey E.
      • Singh R.H.
      • Leeman L.
      • Ogburn T.
      • Fowler K.
      • Greene H.
      Misoprostol for intrauterine device insertion in nulliparous women: a randomized controlled trial.
      ,
      • Swenson C.
      • Turok D.K.
      • Ward K.
      • Jacobson J.C.
      • Dermish A.
      Self-administered misoprostol or placebo before intrauterine device insertion in nulliparous women: a randomized controlled trial.
      ], and in two studies, it increased discomfort [
      • Lathrop E.
      • Haddad L.
      • McWhorter C.P.
      • Goedken P.
      Self-administration of misoprostol prior to intrauterine device insertion among nulliparous women: a randomized controlled trial.
      ,
      • Edelman A.B.
      • Schaefer E.
      • Olson A.
      • Van Houten L.
      • Bednarek P.
      • Leclair C.
      • et al.
      Effects of prophylactic misoprostol administration prior to intrauterine device insertion in nulliparous women.
      ].

      2.8.2 Difficult and unsuccessful insertion

      In a prospective observational trial of women undergoing copper IUD insertion for emergency contraception, 27 of 138 (19.6%) IUD insertions in nulliparous women were unsuccessful compared with 8 of 59 (13.6%) in parous women, although the study was not large enough for the results to be statistically significant [adjusted odds ratio (AOR) for unsuccessful insertion=2.31, 95% CI 0.90–6.52, p=.09] [
      • Dermish A.I.
      • Turok D.K.
      • Jacobson J.C.
      • Flores M.E.
      • McFadden M.
      • Burke K.
      Failed IUD insertions in community practice: an under-recognized problem?.
      ]. Notably, the rates of unsuccessful insertions in both groups were significantly higher than those reported in other studies.
      In a prospective study of 996 insertions in New Zealand, factors associated with an abandoned insertion included nulliparity (AOR=5.19, 95% CI 2.49–10.82). Practitioner-reported difficulty with insertion was also associated with nulliparity (1.98; 95% CI 1.11–3.54); however, 80% of insertions in nulliparous women were rated as “easy” by the inserting doctor. The rate of unsuccessful insertion was 2.3% in women with prior vaginal delivery and 11.2% in nulliparous women (p<.001) [
      • Harvey C.
      • Bateson D.
      • Wattimena J.
      • Black K.I.
      Ease of intrauterine contraceptive device insertion in family planning settings.
      ].

      2.8.3 Differences by device

      Diameter of the insertion tube and size of the inserted product could theoretically be associated with level of pain or with ease of insertion in a nulliparous population. In a study comparing the 13.5-mg LNG-IUS, 19.5-mg LNG-IUS (both with smaller insertion tube and smaller product) and the 52-mg LNG-IUS in nulliparous and parous women, no difference was found in ease of insertion or severe patient-reported pain [
      • Gemzell-Danielsson K.
      • Schellschmidt I.
      • Apter D.
      A randomized, phase II study describing the efficacy, bleeding profile, and safety of two low-dose levonorgestrel-releasing intrauterine contraceptive systems and Mirena.
      ]. An analysis of the nulliparous women showed 0.8% severe pain with insertion of the smaller devices and 1.6% severe pain with the 52 mg LNG-IUS, not a significant difference [
      • Yates J.
      The newly approved IUD: which patients is Skyla appropriate for?.
      ]. In a mixed cohort of 2884 women, of whom 39% were nulliparous, placement of a smaller framed (30 mm × 28 mm) LNG-IUS device containing either 13.5 mg or 19.5 mg LNG was successful in 95.5% of cases on first attempt and in 99.7% after two attempts. Investigators rated placement of these smaller systems as “easy” in 84% of women, and 42% of women reported their pain as either “none” or “mild” [
      • Nelson A.
      • Apter D.
      • Hauck B.
      • Schmelter T.
      • Rybowski S.
      • Rosen K.
      • et al.
      Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial.
      ]. In another study evaluating the ease of placement of the 52-mg LNG-IUS in 509 women (99.8% of whom were parous), 95.9% were inserted at the first attempt and 92% of investigators rated the procedure as “easy.” Most (68.2%) subjects felt either mild pain or no pain during the insertion procedure [
      • Jensen J.T.
      • Nelson A.L.
      • Costales A.C.
      Subject and clinician experience with the levonorgestrel-releasing intrauterine system.
      ].
      In conclusion, nulliparity appears to be associated with increased pain at IUD insertion and increased risk of difficult and unsuccessful insertion. However, most IUD insertions in nulliparous women — as in all women — are well tolerated and successful. Use of ketorolac or 4% viscous lidocaine appears to decrease pain for nulliparous women having IUD insertions, although not without pain from drug administration. Providers should bear in mind that use of non-evidence-based preprocedure agents may impose additional barriers on women wishing to use an IUD but provide no benefit.

      2.9 Are adolescents appropriate candidates for intrauterine contraception?

      Adolescent women in the United States are of particular relevance to this guideline because the vast majority (approximately 89%) are nulliparous [
      Trends in teen pregnancy and childbearing. Office of Adolescent Health, US Department of Health and Human Services.
      ]. According to the American Academy of Pediatrics [
      • Committee on Adolescence
      Contraception for adolescents.
      ] and American Congress of Obstetricians and Gynecologists [
      • Committee on Adolescent Health Care Long-Acting Reversible Contraception Working Group
      • The American College of Obstetricians and Gynecologists
      Committee opinion no. 539: adolescents and long-acting reversible contraception: implants and intrauterine devices.
      ], IUDs should be considered a first-line contraceptive option for adolescent women. Seventy-five percent of pregnancies among U.S. teenagers are unplanned, representing 15 % of all unintended pregnancies annually [
      • Finer L.B.
      • Zolna M.R.
      Declines in unintended pregnancy in the United States, 2008–2011.
      ]. As a group at high risk for unintended pregnancy and given the few contraindications to use, adolescents desiring effective contraception should not be discouraged from considering IUDs. An analysis of data from the National Survey of Family Growth found that from 2008 to 2013, long-acting reversible contraception (LARC) use rates in teens aged 15–19 years old increased from 2.1% to 5.9% (p<.001), and 72% of LARC devices were IUDs [
      • Kavanaugh M.L.
      • Jerman J.
      • Finer L.B.
      Changes in use of long-acting reversible contraceptive methods among U.S. women, 2009–2012.
      ]. Young nulliparous women were significantly less likely than their parous counterparts to have used an IUD (AOR for parous adolescents=11.43, 95% CI 3.61–36.16) [
      • Whitaker A.K.
      • Sisco K.M.
      • Tomlinson A.N.
      • Dude A.M.
      • Martins S.L.
      Use of the intrauterine device among adolescent and young adult women in the United States from 2002 to 2010.
      ].
      A retrospective review of 233 IUD insertions in women younger than 21 showed 5-year continuation rates of 50% in those younger than 18 years and 71.5% in those aged 18–21 (p<.001) [
      • Alton T.M.
      • Brock G.N.
      • Yang D.
      • Wilking D.A.
      • Hertweck S.P.
      • Loveless M.B.
      Retrospective review of intrauterine device in adolescent and young women.
      ]. Teenagers younger than 18 were at greater risk of discontinuation due to either removal or expulsion [hazard ratio (HR)=2.85]. Another retrospective cohort study of 307 adolescents, 77% of whom were nulliparous, found that while the discontinuation rate was higher than those reported in studies of adults, it was lower than rates reported among adolescents using other forms of contraception, and the overall continuation rate at 6 months was 83.3% [
      • Bayer L.L.
      • Jensen J.T.
      • Li H.
      • Nichols M.D.
      • Bednarek P.H.
      Adolescent experience with intrauterine device insertion and use: a retrospective cohort study.
      ]. A cohort study of 179 adolescents in New Zealand, 73% of whom were nulliparous, using the 52-mg LNG-IUS for a variety of indications including contraception found a similarly high 1-year continuation rate of 85%. The expulsion rate was 8% [
      • Paterson H.
      • Ashton J.
      • Harrison-Woolrych M.
      A nationwide cohort study of the use of the levonorgestrel intrauterine device in New Zealand adolescents.
      ].
      More recent data from the CHOICE study, which included 529 women aged 14–19 years, showed a relatively high rate of expulsion of approximately 18% in this group. Compared with older women, adolescent women were significantly more likely to experience an expulsion over a mean follow-up time of 22 months (52-mg LNG-IUS: HR for expulsion 2.26, 95% CI 1.68–3.06; copper device: HR 3.06, 95% CI 1.75–5.33), but there were no differences by parity among adolescents (18.7 per 100 in nulliparous adolescents vs. 18.9 in parous adolescents, p=.47). Continuation rates were otherwise similar in adolescent and older women [
      • Madden T.
      • McNicholas C.
      • Zhao Q.
      • Secura G.M.
      • Eisenberg D.L.
      • Peipert J.F.
      Association of age and parity with intrauterine device expulsion.
      ].
      The literature clearly demonstrates that more education of health care providers is needed to ensure that they have adequate knowledge about the use of IUDs in adolescent women. In a survey of adolescent health care workers, only 77% of respondents said they believed that IUDs are safe for adolescents, and 18% of those respondents stated that they would be unlikely to recommend an IUD to a woman younger than 20 [
      • Kohn J.E.
      • Hacker J.G.
      • Rousselle M.A.
      • Gold M.
      Knowledge and likelihood to recommend intrauterine devices for adolescents among school-based health center providers.
      ]. Other articles have highlighted the challenge of educating providers about the use of IUDs in nulliparous women and adolescents in particular [
      • Tyler C.P.
      • Whiteman M.K.
      • Zapata L.B.
      • Curtis K.M.
      • Hillis S.D.
      • Marchbanks P.A.
      Health care provider attitudes and practices related to intrauterine devices for nulliparous women.
      ,
      • Harper C.C.
      • Blum M.
      • de Bocanegra H.T.
      • Darney P.D.
      • Speidel J.J.
      • Policar M.
      • et al.
      Challenges in translating evidence to practice: the provision of intrauterine contraception.
      ,
      • Madden T.
      • Allsworth J.E.
      • Hladky K.J.
      • Secura G.M.
      • Peipert J.F.
      Intrauterine contraception in Saint Louis: a survey of obstetrician and gynecologists' knowledge and attitudes.
      ].
      In conclusion, although expulsion appears to be more common in adolescents than in older women, the rate of expulsion remains low, and IUD use is safe and effective in this group. The majority of adolescents are excellent candidates for IUDs, given the excellent efficacy and high rate of continuation of the devices.

      2.10 Are IUDs designed specifically for nulliparous women superior to standard devices?

      Smaller and “frameless” (lacking the horizontal arms) IUDs have been developed specifically to fit more easily inside the smaller uterine cavity of nulliparous women. A large prospective trial of 1170 women in Mexico showed a dramatic difference between the performance of the Copper T 380A and that of two copper-based devices designed specifically for nulliparous women [
      • Otero-Flores J.B.
      • Guerrero-Carreño F.J.
      • Vázquez-Estrada L.A.
      A comparative randomized study of three different IUDs in nulliparous Mexican women.
      ]. The continuation rate at 1 year was 29.5% for the Copper T 380A compared with approximately 85% for the two smaller devices. These studies, however, suffered from methodological flaws: the study investigators were not blinded to the method, and complication and removal rates of the Copper T 380A were markedly higher than rates in other published research [
      • Sivin I.
      Problems in the conduct and analysis of “a comparative randomized study of three different IUDs in nulliparous Mexican women”.
      ].
      To date, there is no reliable evidence that other devices, including the 13.5-mg LNG-IUS now available in the United States, confer greater benefits than the 52-mg LNG-IUS and the Copper T 380A in nulliparous women [
      • Aoun J.
      • Dines V.A.
      • Stovall D.W.
      • Mete M.
      • Nelson C.B.
      • Gomez-Lobo V.
      Effects of age, parity, and device type on complications and discontinuation of intrauterine devices.
      ,
      • Gemzell-Danielsson K.
      • Schellschmidt I.
      • Apter D.
      A randomized, phase II study describing the efficacy, bleeding profile, and safety of two low-dose levonorgestrel-releasing intrauterine contraceptive systems and Mirena.
      ,
      • O'Brien P.A.
      • Kulier R.
      • Helmerhorst F.M.
      • Usher-Patel M.
      • d'Arcangues C.
      Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials.
      ].

      3. Conclusion and recommendations for IUD use in nulliparous women

      The following recommendations are based on good and consistent scientific evidence (Level A):
      • The 52-mg, 19.5-mg and 13.5-mg LNG-IUSs and the Copper T 380A IUDs are effective and safe for nulliparous women and should be offered routinely to women of all parities seeking contraception.
      • Nulliparous women seeking highly effective reversible contraception should be advised of the high satisfaction and continuation rates with IUDs.
      • Providers and women can be reassured that nulliparous women who use the IUD do not appear to have higher risks of pelvic infection than parous users and that following IUD removal, fertility is not impaired.
      • Providers and women can be reassured that IUD expulsion rates are not higher among nulliparous women compared to parous women.
      • Use of cervical or vaginal nitroglycerine gel is not recommended to reduce pain during IUD insertion because neither is effective for this indication.
      • Use of 4% viscous lidocaine gel may be beneficial in reducing pain during IUD insertion, although further study is needed to assess pain of gel administration.
      • Use of intramuscular ketorolac may reduce pain during IUD insertion if administered 30 min before the procedure. One fifth of patients felt that the pain of the injection equaled the pain of the IUD insertion.
      • Use of preprocedure misoprostol is not recommended as a method of making IUD insertion easier or less painful.
      The following recommendations are based on limited or inconsistent scientific evidence (Level B):
      • Both nulliparous and parous adolescent women should be considered candidates for IUDs.
      • Provideres and women can be reassured that although nulliparity appears to be associated with increased pain at IUD insertion and increased risk of difficult and unsuccessful insertion, most IUD insertions in nulliparous women are well tolerated and successful.
      The following recommendations are based primarily on consensus or expert opinion (Level C):
      • Providers should advise women that pain and bleeding with copper IUDs may be greater in nulliparous women than in parous women.
      • Women and providers may be reassured that the risk of perforation at IUD insertion is not higher among nulliparous women than among parous women.

      4. Important questions to be answered

      Further research is needed to define the risks and benefits of different IUDs in nulliparous women. Research into methods to reduce discomfort or make insertion technically easier may be of particular benefit to nulliparous women.

      Sources

      PUBMED, MEDLINE and the Cochrane Database were searched for articles related to the use of IUDs in nulliparous and adolescent women published during the period 1980–2016. In addition, the references of publications found through these databases were reviewed to capture any additional articles that may have been missed.

      Authorship

      These guidelines were prepared by Patricia A. Lohr, M.D., M.P.H.; Richard Lyus, M.B.B.S., B.Sc., D.F.S.R.H.; and Sarah Prager, M.D., M.A.S. and were reviewed and approved by the Board of the Society of Family Planning.

      Conflict of interest statement

      None of the authors report any significant relationships with industries relative to these guidelines. The Society of Family Planning receives no direct support from pharmaceutical companies or other industries.

      Intended audience

      This guideline is for Society of Family Planning fellows and any other health care professionals involved in the provision of contraception services. It may also be of interest to those involved in sexual and reproductive health education. This evidence-based review should help guide clinicians providing this care, but it is not intended to dictate clinical care.

      References

        • Trussell J.
        Contraceptive failure in the United States.
        Contraception. 2011; 83 ([Evidence grade: II-2]): 397-404
        • Daniels K.
        • Daugherty J.
        • Jones J.
        • Mosher W.
        Current contraceptive use and variation by selected characteristics among women aged 15–44: United States, 2011–2013.
        Natl Health Stat Report. 2015; ([Evidence grade: II-2]): 1-14
        • Luchowski A.T.
        • Anderson B.L.
        • Power M.L.
        • Raglan G.B.
        • Espey E.
        • Schulkin J.
        Obstetrician-gynecologists and contraception: practice and opinions about the use of IUDs in nulliparous women, adolescents and other patient populations.
        Contraception. 2014; 89 ([Evidence grade: III]): 572-577
        • Tyler C.P.
        • Whiteman M.K.
        • Zapata L.B.
        • Curtis K.M.
        • Hillis S.D.
        • Marchbanks P.A.
        Health care provider attitudes and practices related to intrauterine devices for nulliparous women.
        Obstet Gynecol. 2012; 119 ([Evidence grade: III]): 762-771
        • Stanwood N.L.
        • Garrett J.M.
        • Konrad T.R.
        Obstetrician-gynecologists and the intrauterine device: a survey of attitudes and practice.
        Obstet Gynecol. 2002; 99 ([Evidence grade III]): 275-280
        • Harper C.C.
        • Blum M.
        • de Bocanegra H.T.
        • Darney P.D.
        • Speidel J.J.
        • Policar M.
        • et al.
        Challenges in translating evidence to practice: the provision of intrauterine contraception.
        Obstet Gynecol. 2008; 111 ([Evidence grade: III]): 1359-1369
        • Madden T.
        • Allsworth J.E.
        • Hladky K.J.
        • Secura G.M.
        • Peipert J.F.
        Intrauterine contraception in Saint Louis: a survey of obstetrician and gynecologists' knowledge and attitudes.
        Contraception. 2010; 81 ([Evidence grade: III]): 112-116
      1. (Available online at:) ([Accessed October 2016])
      2. (Available online at:) ([Accessed October 2016])
      3. (Available online at:) ([Accessed October 2016])
      4. (Available online at:) ([Accessed April 2017])
      5. (Available online at:) ([Accessed October 2016])
        • Curtis K.M.
        • Tepper N.K.
        • Jatlaoui T.C.
        • Berry-Bibee E.
        • Horton L.G.
        • Zapata L.B.
        • et al.
        U.S. medical eligibility criteria for contraceptive use, 2016.
        MMWR Recomm Rep. 2016; 65: 1-103
        • Curtis K.M.
        • Jatlaoui T.C.
        • Tepper N.K.
        • Zapata L.B.
        • Horton L.G.
        • Jamieson D.J.
        • et al.
        U.S. selected practice recommendations for contraceptive use, 2016.
        MMWR Recomm Rep. 2016; 65: 1-66
        • Fleming K.L.
        • Sokoloff A.
        • Raine T.R.
        Attitudes and beliefs about the intrauterine device among teenagers and young women.
        Contraception. 2010; 82 ([Evidence grade: III]): 178-182
        • Rose S.B.
        • Cooper A.J.
        • Baker N.K.
        • Lawton B.
        Attitudes toward long-acting reversible contraception among young women seeking abortion.
        J Womens Health. 2011; 20 ([Evidence grade: III]): 1729
        • Spies E.L.
        • Askelson N.M.
        • Gelman E.
        • Losch M.
        Young women's knowledge, attitudes, and behaviors related to long-acting reversible contraceptives.
        Womens Health Issues. 2010; 20 ([Evidence grade: III]): 394
        • Stanwood N.L.
        • Bradley K.A.
        Young pregnant women's knowledge of modern intrauterine devices.
        Obstet Gynecol. 2006; 108 ([Evidence grade: III]): 1417
        • Whitaker A.K.
        • Johnson L.M.
        • Harwood B.
        • Chiappetta L.
        • Creinin M.D.
        • Gold M.A.
        Adolescent and young adult women's knowledge of and attitudes toward the intrauterine device.
        Contraception. 2008; 78 ([Evidence grade: III]): 211
        • Wiebe E.R.
        • Trouton K.J.
        • Dicus J.
        Motivation and experience of nulliparous women using intrauterine contraceptive devices.
        J Obstet Gynaecol Can. 2010; 32 ([Evidence grade: III]): 335-338
        • Nelson A.
        • Apter D.
        • Hauck B.
        • Schmelter T.
        • Rybowski S.
        • Rosen K.
        • et al.
        Two low-dose levonorgestrel intrauterine contraceptive systems: a randomized controlled trial.
        Obstet Gynecol. 2013; 122 ([Evidence grade: I]): 1205-1213
        • Gemzell-Danielsson K.
        • Apter D.
        • Dermout S.
        • Faustmann T.
        • Rosen K.
        • Schmelter T.
        • et al.
        Evaluation of a new, low-dose levonorgestrel intrauterine contraceptive system over 5 years of use.
        Eur J Obstet Gynecol Reprod Biol. 2016; 210 ([Epub ahead of print] [Evidence grade: II-1]): 22-28https://doi.org/10.1016/j.ejogrb.2016.11.022
        • Sivin I.
        • Stern J.
        Long-acting, more effective copper T IUDs: a summary of U.S. experience, 1970–75.
        Stud Fam Plann. 1979; 10 ([Evidence grade: I]): 263-281
        • Aoun J.
        • Dines V.A.
        • Stovall D.W.
        • Mete M.
        • Nelson C.B.
        • Gomez-Lobo V.
        Effects of age, parity, and device type on complications and discontinuation of intrauterine devices.
        Obstet Gynecol. 2014; 123 ([Evidence grade: II-1]): 585-592
        • Eisenberg D.L.
        • Schreiber C.A.
        • Turok D.K.
        • Teal S.B.
        • Westhoff C.L.
        • Creinin M.D.
        • et al.
        Three-year efficacy and safety of a new 52-mg levonorgestrel-releasing intrauterine system.
        Contraception. 2015; 92 ([Evidence Grade: I]): 10-16
        • Gemzell-Danielsson K.
        • Apter D.
        • Hauck B.
        • Schmelter T.
        • Rybowski S.
        • Rosen K.
        • et al.
        The effect of age, parity and body mass index on the efficacy, safety, placement and user satisfaction associated with two low-dose levonorgestrel intrauterine contraceptive systems: subgroup analyses of data from a phase III trial.
        PLoS One. 2015; 10 ([Evidence grade: I]): e0135309
        • Suhonen S.
        • Haukkamaa M.
        • Jakobsson T.
        • Rauramo I.
        Clinical performance of a levonorgestrel-releasing intrauterine system and oral contraceptives in young nulliparous women: a comparative study.
        Contraception. 2004; 69 ([Evidence grade: I]): 407-412
        • Brockmeyer A.
        • Kishen M.
        • Webb A.
        Experience of IUD/IUS insertions and clinical performance in nulliparous women — a pilot study.
        Eur J Contracept Reprod Health Care. 2008; 13 ([Evidence grade: II-2]): 248-254
        • Wildemeersch D.
        • Janssens D.
        • Vrijens M.
        • Weyers S.
        Ease of insertion, contraceptive efficacy and safety of new T-shaped levonorgestrel-releasing intrauterine systems.
        Contraception. 2005; 71 ([Evidence grade: III]): 465-469
        • Peipert J.F.
        • Zhao Q.
        • Allsworth J.E.
        • Petrosky E.
        • Madden T.
        • Eisenberg D.
        • et al.
        Continuation and satisfaction of reversible contraception.
        Obstet Gynecol. 2011; 117 ([Evidence grade: II-2]): 1105-1113
        • Hall A.M.
        • Kutler B.A.
        Intrauterine contraception in nulliparous women: a prospective survey.
        J Fam Plann Reprod Health Care. 2016; 42 ([Evidence grade II-2]): 36-42
        • Römer T.
        • Linsberger D.
        User satisfaction with a levonorgestrel-releasing intrauterine system (LNG-IUS): data from an international survey.
        Eur J Contracept Reprod Health Care. 2009; 14 ([Evidence grade: III]): 391-398
        • Hubacher D.
        Copper intrauterine device use by nulliparous women: review of side effects.
        Contraception. 2007; 75 (Suppl). [Evidence grade: I]: S8-11
        • Madden T.
        • McNicholas C.
        • Zhao Q.
        • Secura G.M.
        • Eisenberg D.L.
        • Peipert J.F.
        Association of age and parity with intrauterine device expulsion.
        Obstet Gynecol. 2014; 124 ([Evidence grade II-1]): 718-726
        • Heinemann K.
        • Reed S.
        • Moehner S.
        • Minh T.D.
        Risk of uterine perforation with levonorgestrel-releasing and copper intrauterine devices in the European active surveillance study on intrauterine devices.
        Contraception. 2015; 91 ([Evidence grade: I]): 274-279https://doi.org/10.1016/j.contraception.2015.01.007
        • Caliskan E.
        • Oztürk N.
        • Dilbaz B.O.
        • Dilbaz S.
        Analysis of risk factors associated with uterine perforation by intrauterine devices.
        Eur J Contracept Reprod Health Care. 2003; 8 ([Evidence grade: II-1]): 150-155
        • Veldhuis H.
        • Vos A.
        • Lagro-Janssen A.
        Complications of the intrauterine device in nulliparous and parous women.
        Eur J Gen Pract. 2004; 10 ([Evidence grade: III]): 82-87
        • Farley T.M.
        • Rosenberg M.J.
        • Rowe P.J.
        • Chen J.H.
        • Meirik O.
        Intrauterine devices and pelvic inflammatory disease: an international perspective.
        Lancet. 1992; 339 ([Evidence grade: II-3]): 785-788
        • Jatlaoui T.C.
        • Simmons K.B.
        • Curtis K.M.
        The safety of intrauterine contraception initiation among women with current asymptomatic cervical infections or at increased risk of sexually transmitted infections.
        Contraception. 2016 Dec; 94: 701-712
        • Turok D.K.
        • Eisenberg D.L.
        • Teal S.B.
        • Keder L.M.
        • Creinin M.D.
        A prospective assessment of pelvic infection risk following same-day sexually transmitted infection testing and levonorgestrel intrauterine system placement.
        Am J Obstet Gynecol. 2016; 215: 599.e1-599.e6https://doi.org/10.1016/j.ajog.2016.05.017
        • Hubacher D.
        • Lara-Ricalde R.
        • Taylor D.J.
        • Guerra-Infante F.
        • Guzman-Rodriguez R.
        Use of copper intrauterine devices and the risk of tubal infertility among nulligravid women.
        N Engl J Med. 2001; 345 ([Evidence grade: II-1]): 561
        • Doll H.
        • Vessey M.
        • Painter R.
        Return of fertility in nulliparous women after discontinuation of the intrauterine device: comparison with women discontinuing other methods of contraception.
        BJOG. 2001; 108 ([Evidence grade: II-2]): 304-314
        • Andersson K.
        • Batar I.
        • Rybo G.
        Return to fertility after removal of a levonorgestrel-releasing intrauterine device and Nova-T.
        Contraception. 1992; 46 ([Evidence grade II-2]): 575-584
        • Delbarge W.
        • Bátár I.
        • Bafort M.
        • Bonnivert J.
        • Colmant C.
        • Dhont M.
        • et al.
        Return to fertility in nulliparous and parous women after removal of the GyneFix intrauterine contraceptive system.
        Eur J Contracept Reprod Health Care. 2002; 7 ([Evidence grade II-3]): 24-30
        • Harvey C.
        • Bateson D.
        • Wattimena J.
        • Black K.I.
        Ease of intrauterine contraceptive device insertion in family planning settings.
        Aust N Z J Obstet Gynaecol. 2012; 52 ([Evidence grade II-2]): 534-539
        • Allen R.H.
        • Carey M.S.
        • Raker C.
        • Goyal V.
        • Matteson K.
        A prospective cohort study of pain with intrauterine device insertion among women with and without vaginal deliveries.
        J Obstet Gynaecol. 2014; 34 ([Evidence grade II-2]): 263-267
        • Brown W.M.
        • Trouton K.
        Intrauterine device insertions: which variables matter?.
        J Fam Plann Reprod Health Care. 2014; 40 ([Evidence grade II-2]): 117-121
        • Hubacher D.
        Pain from copper intrauterine device insertion: randomized trial of prophylactic ibuprofen.
        Am J Obstet Gynecol. 2006; 195 ([Evidence grade: I]): 1272-1277
        • Bednarek P.H.
        • Creinin M.D.
        • Reeves M.F.
        • Cwiak C.
        • Espey E.
        • Jensen J.T.
        Prophylactic ibuprofen does not improve pain with IUD insertion: a randomized trial. Post-aspiration IUD randomization (PAIR) study trial group.
        Contraception. 2014; 91 ([Evidence grade I]): 193-197
        • Espey E.
        • Singh R.H.
        • Leeman L.
        • Ogburn T.
        • Fowler K.
        • Greene H.
        Misoprostol for intrauterine device insertion in nulliparous women: a randomized controlled trial.
        Am J Obstet Gynecol. 2014; 210 ([Evidence grade I]): 208
        • Swenson C.
        • Turok D.K.
        • Ward K.
        • Jacobson J.C.
        • Dermish A.
        Self-administered misoprostol or placebo before intrauterine device insertion in nulliparous women: a randomized controlled trial.
        Obstet Gynecol. 2012; 120 ([Evidence grade I]): 341-347
        • Lopez L.M.
        • Bernholc A.
        • Zeng Y.
        • Allen R.H.
        • Bartz D.
        • O'Brien P.A.
        • et al.
        Interventions for pain with intrauterine device insertion.
        Cochrane Database Syst Rev. 2015; 7 ([Evidence grade I]): CD007373
        • Ngo L.L.
        • Ward K.K.
        • Mody S.K.
        Ketorolac for pain control with intrauterine device placement: a randomized controlled trial.
        Obstet Gynecol. 2015; 126 ([Evidence grade I]): 29-36
        • Allen R.H.
        • Raker C.
        • Goyal V.
        Higher dose cervical 2% lidocaine gel for IUD insertion: a randomized controlled trial.
        Contraception. 2013; 88 ([Evidence grade I]): 730-736
        • Rapkin R.B.
        • Achilles S.L.
        • Boraas C.
        • Cremer M.
        • Schwarz E.B.
        • Chen B.A.
        Self-administered lidocaine gel for intrauterine device insertion in nulliparous women: a randomized controlled trial.
        Obstet Gynecol. 2016 Sep; 128 ([Evidence grade I]): 621-628
        • Bednarek P.H.
        • Micks E.A.
        • Edelman A.B.
        • Li H.
        • Jensen J.T.
        The effect of nitroprusside on IUD insertion experience in nulliparous women: a pilot study.
        Contraception. 2013; 87 ([Evidence grade I]): 421-425
        • Micks E.A.
        • Jensen J.T.
        • Bednarek P.H.
        The effect of nitroglycerin on the IUD insertion experience in nulliparous women: a pilot study.
        Contraception. 2014; 90 ([Evidence grade I]): 60-65
        • Tornblom-Paulander S.
        • Tingåker B.K.
        • Werner A.
        • Liliecreutz C.
        • Conner P.
        • Wessel H.
        • et al.
        Novel topical formulation of lidocaine provides significant pain relief for intrauterine device insertion: pharmacokinetic evaluation and randomized placebo-controlled trial.
        Fertil Steril. 2015; 103 ([Evidence grade I]): 422-427https://doi.org/10.1016/j.fertnstert.2014.10.026
        • Ward K.
        • Jacobson J.C.
        • Turok D.K.
        • Murphy P.A.
        A survey of provider experience with misoprostol to facilitate intrauterine device insertion in nulliparous women.
        Contraception. 2011; 84 ([Evidence grade III]): 594-599
        • Lathrop E.
        • Haddad L.
        • McWhorter C.P.
        • Goedken P.
        Self-administration of misoprostol prior to intrauterine device insertion among nulliparous women: a randomized controlled trial.
        Contraception. 2013; 88 ([Evidence grade I]): 725-729
        • Edelman A.B.
        • Schaefer E.
        • Olson A.
        • Van Houten L.
        • Bednarek P.
        • Leclair C.
        • et al.
        Effects of prophylactic misoprostol administration prior to intrauterine device insertion in nulliparous women.
        Contraception. 2011; 84 ([Evidence grade I]): 234-239
        • Dermish A.I.
        • Turok D.K.
        • Jacobson J.C.
        • Flores M.E.
        • McFadden M.
        • Burke K.
        Failed IUD insertions in community practice: an under-recognized problem?.
        Contraception. 2013; 87 ([Evidence grade II-2]): 182-186
        • Gemzell-Danielsson K.
        • Schellschmidt I.
        • Apter D.
        A randomized, phase II study describing the efficacy, bleeding profile, and safety of two low-dose levonorgestrel-releasing intrauterine contraceptive systems and Mirena.
        Fertil Steril. 2012; 97 ([Evidence grade I]): 616-622
        • Yates J.
        The newly approved IUD: which patients is Skyla appropriate for?.
        OBG Manag. 2013; 25 ([Evidence grade III])
        • Jensen J.T.
        • Nelson A.L.
        • Costales A.C.
        Subject and clinician experience with the levonorgestrel-releasing intrauterine system.
        Contraception. 2008; 77 ([Evidence grade II-3]): 22-29
      6. Trends in teen pregnancy and childbearing. Office of Adolescent Health, US Department of Health and Human Services.
        (Available at:) ([Accessed March 2015])
        • Committee on Adolescence
        Contraception for adolescents.
        Pediatrics. 2014; 134: 1244-1256
        • Committee on Adolescent Health Care Long-Acting Reversible Contraception Working Group
        • The American College of Obstetricians and Gynecologists
        Committee opinion no. 539: adolescents and long-acting reversible contraception: implants and intrauterine devices.
        Obstet Gynecol. 2012; 120: 983-988
        • Finer L.B.
        • Zolna M.R.
        Declines in unintended pregnancy in the United States, 2008–2011.
        N Engl J Med. 2016; 374 ([Evidence grade: II-2]): 843-852
        • Kavanaugh M.L.
        • Jerman J.
        • Finer L.B.
        Changes in use of long-acting reversible contraceptive methods among U.S. women, 2009–2012.
        Obstet Gynecol. 2015; 126 ([Evidence grade : II-2]): 917-927
        • Whitaker A.K.
        • Sisco K.M.
        • Tomlinson A.N.
        • Dude A.M.
        • Martins S.L.
        Use of the intrauterine device among adolescent and young adult women in the United States from 2002 to 2010.
        J Adolesc Health. 2013; 53 ([Evidence grade III]): 401-406
        • Alton T.M.
        • Brock G.N.
        • Yang D.
        • Wilking D.A.
        • Hertweck S.P.
        • Loveless M.B.
        Retrospective review of intrauterine device in adolescent and young women.
        J Pediatr Adolesc Gynecol. 2012; 25 ([Evidence grade III]): 195-200
        • Bayer L.L.
        • Jensen J.T.
        • Li H.
        • Nichols M.D.
        • Bednarek P.H.
        Adolescent experience with intrauterine device insertion and use: a retrospective cohort study.
        Contraception. 2012; 86 ([Evidence grade II-2]): 443-451
        • Paterson H.
        • Ashton J.
        • Harrison-Woolrych M.
        A nationwide cohort study of the use of the levonorgestrel intrauterine device in New Zealand adolescents.
        Contraception. 2009; 79 ([Evidence grade III]): 433-438
        • Kohn J.E.
        • Hacker J.G.
        • Rousselle M.A.
        • Gold M.
        Knowledge and likelihood to recommend intrauterine devices for adolescents among school-based health center providers.
        J Adolesc Health. 2012; 51 ([Evidence grade III]): 319-324
        • Otero-Flores J.B.
        • Guerrero-Carreño F.J.
        • Vázquez-Estrada L.A.
        A comparative randomized study of three different IUDs in nulliparous Mexican women.
        Contraception. 2003; 67 ([Evidence grade: II-2]): 273-276
        • Sivin I.
        Problems in the conduct and analysis of “a comparative randomized study of three different IUDs in nulliparous Mexican women”.
        Contraception. 2004; 69 ([Evidence grade: III]): 259-260
        • O'Brien P.A.
        • Kulier R.
        • Helmerhorst F.M.
        • Usher-Patel M.
        • d'Arcangues C.
        Copper-containing, framed intrauterine devices for contraception: a systematic review of randomized controlled trials.
        Contraception. 2008; 77 ([Evidence grade: I]): 318-327